Due to unprecedented demand, please call, e-mail, or chat to check on stock before purchasing.  Free Shipping orders of $200 or more

Victron Orion-Tr 24/12-9A (110W) Isolated DC-DC Converter ORI241210110R

Remote on-off
The remote on-off eliminates the need for a high current switch in the input wiring. The remote on-off can be operated with a low power switch or by for example the engine run/stop switch (see manual). 

Adjustable output voltage: 
The adjustable output voltage can also be used as a battery charger. For example to charge a 12 Volt starter or accessory battery in an otherwise 24V system. 
All models are short circuit proof and can be paralleled to increase output current.
An unlimited number of units can be connected in parallel. 

IP43 protection
When installed with the screw terminals oriented downwards. 

Screw terminals
No special tools needed for installation.

Input fuse
On 12V and 24V input models only.

$67.15
OR
FreeShippingLogo_Horizontal

Victron Orion-Tr 24/12-9A (110W) Isolated DC-DC Converter ORI241210110R

SKU
302452
Price
$67.15
MPN
ORI241210110R
Manufacturer
Victron
  • Features
  • Tech Notes
  • Downloads
  • Accessories
  • Warranties
  • Videos
  • Reviews
  • 1. Select a cool, dry and ventilated area.

    2. Connect the input supply cables.

    Note: the 12V and 24V input models have an internal input fuse (not replaceable). The 48V models do not have this fuse: external fuse required.

    3. Optional remote on/off: replace the wire bridge on the green connector by a switch (switched current is less than 100mA), or remove the wire bridge and connect the left-hand terminal of the green connector to the battery plus with a switch (this could for example be the engine run/stop switch).

    4. Adjustable output voltage:
    The default values are 12,2V, 24,2V or 48,2V, depending on the model. The output voltage can be set between approximately - 15% to + 25% of the default output voltage by turning the potentiometer. Turn counter clockwise to decrease the output voltage. Turn clockwise to increase the output voltage.

    5. The output is overload and short circuit proof. The converters can therefore be connected in parallel, and can be used to float-charge a battery. (always adjust the output voltage before connecting in parallel or connecting a battery) 

    6. Connect the load. The converter is now ready for use.