Discontinued – Call for Replacement
The VE.Direct port can be connected to:
Fully configurable:
Monitoring:
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters, we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Cont. power at 25°C (1) |
1200VA |
Cont. power at 25°C / 40°C |
1000 / 850W |
Peak power |
2200W |
Output AC voltage / frequency (adjustable) | 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1% |
Input voltage range | 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V |
DC low shut down (adjustable) | 9,3 / 18,6 / 37,2V |
DC low restart and alarm (adjustable) | 10,9 / 21,8 / 43,6V |
Battery charged detect (adjustable) | 14,0 / 28,0 / 56,0V |
Max. efficiency | 91 / 91 / 92% |
Zero-load power | 7 / 8 / 10W |
Default zero-load power in ECO mode (default retry interval: 2,5 s, adjustable) |
1 / 1,5 / 3,0W |
ECO mode stop and start power setting | Adjustable |
Protection (2) | a - f |
Operating temperature range | -40 to +65°C (fan assisted cooling) Derate 1,25% per °C above 40°C |
Humidity (non-condensing) | max 95% |
ENCLOSURE
Material & Colour |
Steel chassis and plastic cover (blue Ral 5012) |
Battery-connection |
Screw terminals |
Maximum cable cross-section | 35 / 25 / 25mm2 / AWG2 / 4 / 4 |
Standard AC outlets | 230V: Schuko (CEE 7/4), IEC-320 (male plug included) UK (BS 1363), AU/NZ (AS/NZS 3112) 120V: Nema 5-15R, GFCI |
Protection category | IP 21 |
Weight | 7,4kg / 16,3lbs |
Dimensions (hxwxd) mm | 117 x 232 x 362 |